Structure Type of Building Pre-engineered building from reputed manufacturer
Height of Warehouse 12m at Eave
Pitch of roof 1:20 slope
Roofing 0.6mm Bare-galvalume standing seam roof
Cladding (Side walls) 0.5mm Colour coated
Insulation 8mm Air bubble insulation
Crane Provision 10 MT (Provision)
Wall height 3m high brick wall from Floor level
Natural lighting 3% of Roof
Ventilation Natural Ventilation through Roof monitor
Docking Main docking from Single side for better utilisation of Space
Minor docking all around warehouse
27m of Apron available in front of major docking
1.2m (4FT) high to maintain easy loading/unloading
Fire Escape Steel Doors with Panic bar as per norms
Staircases to the road level/ground level with MS painted handrails
Flooring VDF flooring with Trimix Finish
5 MT/m2 Capacity
Toilet Toilet for Works with proper facility
Electrical Works Three phase power supply at tap-off point
Power will be provided at the rate of 10 watts per sq. mtr
Firefighting System Tap-off points for the hydrant system
System tap off for roof sprinkler system (Provision)
Common Facility Truck Parking
Weigh Bridge
Sewage treatment Plant
RCC road with Proper Drainage system